OpenID logon

  Previous topic Next topic Print this topic Mail us feedback on this topic!

  Default  
  Web part control ID: Serves as an identifier for the web part. This ID must be unique within the context of each page template. The value of this property may only contain alphanumeric characters and the underscore character ( _ ).  
  Web part title: Title of the web part displayed on the Design tab of CMS Desk and in on-site editing mode. If empty, the value of the Web part control ID property is used for this purpose.  
   

  Visibility  
  Visible: Indicates if the web part should be displayed.  
  Hide on subpages: Indicates if the web part should be hidden on sub-pages. If checked, the web part will not be displayed on documents that inherit the web part from a parent document.  
  Show for document types: Contains a list of document types on which the web part should be displayed. If the currently selected document uses the page template containing this web part, but its type is not specified by this property, the web part will be hidden. The document types in the list must be specified by their code names and separated by semicolons (;). If empty, the web part will be displayed on all document types.  
  Display to roles: Contains a list of roles to which the web part should be displayed. This may be used to implement documents with specific functionality for different types of users. The roles in the list must be specified by their code names and separated by semicolons (;). If empty, the web part will be displayed to all users.  
   

  OpenID  
  Providers: Configures the providers used for OpenID login. Each provider must be specified on a new line. A total number of 3 parameters should be included for each provider: 1 - provider display name, 2 - provider login URL, 3 - provider icon name placed in the ~/CMSWebParts/Membership/OpenID/OpenID_files/ folder. Each parameter must be separated by '|'. The third parameter is optional and the default OpenID icon will be displayed if it is not specified. The URL must be a login URL for the OpenID provider. If the username (or blog name, user id, etc.) is part of the URL, then use the ##username## macro to replace the username part of the URL. Example: myOpenID|http://##username##.myopenid.com/|myopenid.ico  
  Display textbox: Indicates if the OpenID provider textbox should be visible. If disabled, then only the login button will be displayed.  
   

  Sign in/out button  
  Sign in text: Sets the text of the sign in link.  
  Sign out text: Sets the text of the sign out link.  
  Show sign out: If enabled, the web part will display a sign out link for authenticated users.  
  Show as button: If enabled, buttons will be displayed instead of standard text links.  
  Sign in image: Specifies the URL of an image that will be used for the sign in button if the Sign in text property is empty.  
  Sign out image: Specifies the URL of an image that will be used for the sign out button if the Sign out text property is empty.  
   

  Required data for new users  
  Birth Date: Indicates if the user's birth date should be requested during the registration process.  
  Country: Indicates if the user's country should be requested during the registration process.  
  E-mail: Indicates if the e-mail should be requested during the registration process.  
  FullName: Indicates if the user's full name should be requested during the registration process.  
  Gender: Indicates if the user's gender should be requested during the registration process.  
  Language: Indicates if the user's language should be requested during the registration process.  
  Nickname: Indicates if the user's nickname should be requested during the registration process.  
  PostalCode: Indicates if the user's postal code should be requested during the registration process.  
  TimeZone: Indicates if the user's time zone should be requested during the registration process.  
   

  Extended settings  
  Notify administrator about new registrations: Indicates if a notification e-mail should be sent to the administrator when a new user registers via the web part.  
   

  Conversion tracking  
  Track conversion name: Selects the conversion that will be logged when a user successfully completes their registration via the web part.  
  Conversion value: Sets a number that will be recorded along with the conversion when the tracked action is performed. The values are cumulative, i.e. when a conversion hit is logged, the specified value will be added to the total sum previously recorded for this conversion. If you wish to specify a dynamic value, insert an appropriate macro expression by clicking the arrow icon (Edit value) next to the field.  
   

  Web part container  
  Web part container: Specifies the name of the container (box) to be displayed around the web part. Only containers defined in Site Manager -> Development -> Web part containers can be selected. The selected container can be edited directly by using the Edit button.  
  Container title: Sets a title for the container. This title is displayed only if the {%ContainerTitle%} macro is used in the code of the container.  
  Container CSS class: CSS class used for the container. Applied only if the {%ContainerCSSClass%} macro is used as the value of the Class attribute in the code of the container.  
  Container custom content: Custom content to be used in the container. Applied only if the {%ContainerCustomContent%} macro is used in the code of the container.  
  Hide container on subpages: Indicates if the web part container should be hidden on sub-pages.  
   

  HTML Envelope  
  Content before: HTML content placed before the web part. Can be used to display a header or add some encapsulating code, such as <div> or <table> elements to achieve the required layout.  
  Content after: HTML content placed after the web part. Can be used to display a footer or close the tags contained in the ContentBefore value, such as </div> or </table> elements.  
   

  AJAX  
  Use update panel: Indicates if an AJAX UpdatePanel container should be used for this web part.  
   

  Time zones  
  Time zone: Specifies the type of time zone used for the content of the web part.  
  Custom time zone: May be used to assign a custom time zone specifically for the content of this web part. If selected, the time zone will be used regardless of current user or website time zone settings.  
   

  Performance  
  Disable view state: Indicates if view state should be disabled for this web part.  
  Disable macros: If checked, macros contained in the values of the web part's properties will no longer be resolved.  
  Partial cache minutes: Sets the number of minutes for which the output HTML code of the web part should remain cached. This process is similar to full-page caching, but only for the code of the web part specifically. If left empty or set to 0, partial caching will be not be used for the web part.  
  Partial cache dependencies: Contains a list of cache keys on which the partial cache of the web part depends. When the specified cache items change, the partial cache of the web part is deleted. Each line may contain a single item only. If the 'Use default cache dependencies' box is checked, the default dependencies will be used, which include all possible object changes that could affect the specific web part.  
   

  Output filter  
  Filter output HTML of web part: If checked, the output code of this web part is processed by the output filters  
  Resolve URLs: If checked, the filter removes the "~" character in relative URLs and replace it with the root URL of the website.  
  Fix attributes: If checked, the filter ensures that all HTML tag attributes are in valid XHTML format.  
  Fix Javascript: If checked, the filter ensures that the type and language attributes are included in all <script> tags.  
  Fix lower case: If checked, the filter ensures that all HTML tags and attributes are generated in lower case.  
  Fix self closing tags: If checked, the filter ensures that HTML tags without end tags are properly closed.  
  Fix tags: If checked, the filter replaces tags that are not XHTML valid with appropriate equivalents (<strong> instead of <b>, <em> instead of <i>).  
  Fix HTML5: If checked, the filter replaces attributes that are obsolete in HTML5 with CSS classes named in format <attribute name>_<attribute value>. The affected attributes are: cellpadding, cellspacing, width, height, border, align, valign  
  Convert TABLE tags to DIV tags: If enabled, the TABLE tags in the output are automatically converted to DIV tags with CSS class corresponding to the tag name (table, tr, td, etc.) Blocks of HTML code can be optionally marked with class="_divs" or class="_nodivs" to allow or disable conversion for that particular block of code.  
   

Help URL: http://devnet.kentico.com/docs/webparts/index.html?OpenIDlogon_properties.htm